With the ever-increasing use of guitars, the demand for guitar amps has also increased significantly. The market is replete with guitar amps, but you need to settle on a reliable brand if you have to get an amp. The reason is that it saves you from the trouble of searching here and there.
A renowned brand can get you a product that is well suited for your musical needs. Guitar enthusiasts must have heard of the Bugera brand that has attracted the attention of many users. It won’t be wrong to call the Bugera amps ‘state-of-the-art’. Bugera 6260 offers exceptional clarity and output levels, thanks to its features.
But it is also accompanied by a few problems that can keep the musicians from buying it. In this article, we will address the most common Bugera 6260 problems and suggest their solutions. Let’s proceed without further adieu.
Bugera 6260 Problems
- Sparkling In The Amp
Bugera 6260 has dots in the body, which makes it easy for you to take a look inside and see that there is sparkling in the amp. Although the sparkling issue is not that common, it is still frustrating and needs to be resolved. There are multiple causes behind this problem, including voltage fluctuation, short circuits, and much more.
It’s not just the sparkling that results from such causes, but they can also affect the other components of the amp and malfunction them for good. That is why, as soon as you notice the sparkling, look for a short circuit. Replace the burnt cables and any other component of the unit that has been damaged. This will kill the sparkling.
- Drop Of Volume
You can expect Bugera 6260 to act strange at times. In simple words, if you are performing a gig, you might notice that the amp has dropped the volume. There are several other signs too. The amp is very quiet when you turn it on. As far as the master volume is concerned, it doesn’t work at all.
You might also hear a weak sound from the distortion channel. The volume of that sound is equivalent to that of headphones. There is no sound from the clean channel. The first thing that you should do is change the preamp tubes one by one. However, that’s not likely to get you results.
Even if you swap the power tubes, there is nothing rewarding that you can get. Nobody wants to get in touch with a technician because they can misguide you and get your product ruined. Anyways, the issue is mainly related to the power tubes. The swapping of the power tubes could not get you results if you didn’t bias them.
- Rattling Noise
Users of the Bugera 6260 amp have complained about the issue of rattling noise very often. You can try multiple troubleshooting tips to diagnose and solve the problem. The first thing that you need to do is remove the preamp tubes from the unit and cover them with the rubber damper things.
If that doesn’t work, replace the tubes and power on the amp. You might not hear any sound from the amp. There is no such engagement from the power tubes. You get the response from the gain knob, but the volume knob gives nothing. Sometimes the simple fix to this problem requires you to just turn off the amp and then turn it again.
The noise just disappears, but you must try something else if this noise issue keeps getting back. Make sure you check the connections of cables, and none of them is loose or too tight. There is another situation where the interference of other devices with your sound system can make a noise.
Guitarists frequently use phones for charts on the stage. Therefore, it is a common sight to see cell phones lying around guitars and amps. Any of those nearby devices, including a smartphone or a laptop, should be kept distant from the amp. The next thing you should check is the tube number and the sockets you plugged the tubes into.
In many cases, users remove the preamp tubes and reinstall them, but they rearrange the tube number and put the tubes in the wrong sockets. That’s what causes the power tubes to not engage. Let’s take an example where you pulled out a 12AX7. Do not make the mistake of putting it back in a 12AU7.
Both of these sockets are different in their gain structures. In order to identify the tube with the rattling noise, give a light tap to all the tubes and get your faulty tube. Get it replaced but install the new one after you bias it.
There is no doubt that the component of the amplifier that faces the most problems is the power tubes. But you can cause more problems to your amps if you don’t identify the real cause behind the power tube malfunctioning.
- Crackling Noise
The Bugera 6260 amp can release sparks by the tube and shut off. It cannot get powered on even after you try it multiple times. You can get back the power by installing a new fuse in the unit. But after this, the amp works with a horrible crackling sound when you play it.
The best suggestion, in this case, is that the amp should be kept turned off until you get it repaired by the technician. The problem of crackling results from a serious high volt connection. If you have just bought your amp and it gives you this issue, send it back for a refund.
Otherwise, take it to the technician as soon as possible. You should not attempt to fix it yourself because either the amp can get damaged or die altogether.
- Not Powering On
Although the problem of amps not getting powered on is pretty common, this problem is very inconvenient for the users of Bugera 6260 as it already poses plenty of problems. However, all you need to do is check the power unit. If the unit is not causing the problem, it might be its soldering joints.
At the very first identification of a problem with the soldering joints, you need to get them replaced. It is recommended to let an authorized technician do this task for you because it can get dangerous. Only a professional knows how to deal with a problem this severe.
- No Sound At All
Sometimes the amp fails to give any sound. Even if you get the sound back somehow, it’s not permanent and steady. It keeps crackling back to life. The simplest way to solve this problem is to turn off the amp and reset it. However, that solution is not long-lasting because the amp starts tripping again in no time.
Plug the headphones into the phone pocket and unplug them after a while. It is likely to get back the sound. There is no need to doubt guitars and cables for no sound because if they are properly plugged into the computer, they are working alright.
You can try removing the dirt from the phone socket by using a switch cleaner. Take the jack out and insert it back again. Do this a couple of times and see if that works.
The worst part, apart of what was mentioned (power connectors may burn) is when the channel switches change by themselves. You have to power off and on again. It may happen in the middle of a gig. I was able to correct it partially yet that’s due to ill design (circuitry depending on very high transistor gain). Due to lack of schematics could not proceed any further. I do not recommend buying this amplifier at all, even at cheap prices. And I do not like its harsh sound, but there is an excuse, I mostly play the blues…
Mine doesn’t gig; It sits in one spot. Its probably less than a year old and now doesn’t turn on right away…I flip the switches and it takes about 20 minutes for the last setting (green or orange light) to light up where it used to turn on right away and slowly warm up getting louder.
….And why does it turn on with the reverb and fx loop engaged every time?? Weird. I do love the sound quality of this amp though…have a selection of pedals and this beast likes to play.